White 1521 Dokumentacja Strona 1

Przeglądaj online lub pobierz Dokumentacja dla Maszyny do szycia White 1521. White 1521 Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Emerson Inspire

TROUBLESHOOTING1HDEZ-1521Emerson Inspire™Thermostat/InterfaceEquipment ControlInstallation Instructions

Strona 2

10INSTALLATIONInstallationFig. 6 - System Dehumidication with variable speed blower. For systems where low speed requires connect to normally open 24

Strona 3 - & SPECIFICATIONS

11INSTALLATIONInstallationThermostat 1) Pull the thermostat o the base using tabs shown above.2) Place base over wire hole in wall and mark mountin

Strona 4

12INSTALLATIONThermostatEquipment ControlR12C12CRData 1Data 224 VAC (Common24 VAC (Hot)Fig. 8 - Thermostat and Equipment Control WiringRJ-11 Connectio

Strona 5 - Equipment Control

13ADVANCED INSTALLER MENUFrom the Home screen press the and buttons at the same time for three seconds. Press Enter button to save any changes an

Strona 6

14ADVANCED INSTALLER MENUPress button to select Setup.Communicating DevicesThis menu item will list each piece of system equipment. Press butto

Strona 7

15ADVANCED INSTALLER MENUIndoorGA2 – 2 stage gas furnaceGA1 – 1 stage gas furnaceEL2 – 2 stage electric heatEL1 – 1 stage electric heatFAN – Indoor fa

Strona 8

16ADVANCED INSTALLER MENUHUMOFF – No humidier equipmentSYS – Humidier, powered using 24V from systemIND – Humidier, powered using independent 24V s

Strona 9

17ADVANCED INSTALLER MENUUSB Upload The USB Upload menu displays a list of thermostat parameters that can be loaded to the thermostat from a USB memo

Strona 10 - Installation

18ADVANCED INSTALLER MENUThermostat SummaryIndicates the thermostat’s software and version.Heat Pump Lockout (outdoor sensor required)Available only f

Strona 11 - Thermostat

19ADVANCED INSTALLER MENUAux Lockout Temperature (outdoor sensor required)Available for heat pump systems. This setting is the maximum outdoor tempera

Strona 12

2ATTENTION: MERCURY NOTICEThis product does not contain mercury. However, this product may replace a product that contains mercury.Mercury and product

Strona 13 - Advanced Installer Menu

20ADVANCED INSTALLER MENUInstallation TestPerforms an equipment test to verify proper installation and performance. Only operable on communicating sys

Strona 14 - Communicating Devices

21MAIN MENUNavigating through your thermostat menusYour thermostat features a simplied easy to understand menu structure.• Press to enter the Main

Strona 15

22MAIN MENUTime and Day DisplayWhen turned on, the current time and day are displayed on the home screen.Outdoor Temp DisplayWhen turned on, the outdo

Strona 16

23MAIN MENUCooling ProgramAfter entering Heating Program, press to highlight “Switch to Cool Program” and press , or enter Cooling Program on the M

Strona 17 - Faults Status

24MAIN MENUAir Filter Maintenance / Service Reminder / Humidier Maintenance Default for each is O. When set to On, a maintenance reminder will appea

Strona 18 - Thermostat Summary

25MAIN MENUBeeper – Default is On. Turns audible prompt on to indicate when a button is pressed.Cycle Humidier – Default if O. This feature provides

Strona 19 - Heat Cycle Rate

26MAIN MENUEMR (Energy Management Recovery)Default is On. With EMR selected On, the heating or cooling system will start early so the temperature in y

Strona 20 - Check System Operation

27MAIN MENUTemperature Display Adjust – Default is 0°. Your thermostat was accurately calibrated at the factory. However, this option allows you to ch

Strona 21 - Clock and Display Settings

28TROUBLESHOOTINGSymptom Possible Cause Correction ActionNo Heat/No Cool/No Fan (common problems)1. Blown fuse or tripped circuit breaker. 2. Power sw

Strona 22 - Heating Program

29TROUBLESHOOTINGSymptom Possible Cause Correction ActionNo Cool1. Cooling system requires service. Heat, Cool or Fan Runs Constantly1. Possible short

Strona 23 - Thermostat Settings

3APPLICATIONS & SPECIFICATIONSApplications and Speci cationsElectrical Rating:Input-Hardwire ... 20 to 30 VACTermina

Strona 24 - Main Menu

30TROUBLESHOOTINGEquipment Control Fault CodesNumber Displayed in 7 Segment LEDComfort Alert FaultP Trip1Long Run Time2System Pressure Trip3Short Cycl

Strona 26

www.white-rodgers.comwww.emersonclimate.comWhite-Rodgers is a business of Emerson Electric Co.The Emerson logo is a trademark and service mark of Eme

Strona 27

4INSTALLATIONInstallationReduce installation time with a USB1. Go to www.white-rodgers.com2. Enter 1HDEZ-1521 in the Model Number Search  eld3. Sel

Strona 28 - Reset Operation

5INSTALLATIONEquipment ControlMount on wall or exterior surface of HVAC equipment. Control has four mounting holes. Wall anchors and screws are provid

Strona 29 - Troubleshooting

6INSTALLATION Equipment Control Terminals Operation / Function R ... 24 VAC Transformer RC ...

Strona 30 - Equipment Control Fault Codes

7INSTALLATIONRJ-11 Connection for Configuration Plug-In toolStatus/Fault7-Segment LEDWiring to ThermostatR and C from HVAC terminal strip or system tra

Strona 31

8INSTALLATIONInstallationFig. 1 - Typical Connection of a Single Stage or Multi-Stage System*Factory installed jumper between RH and RCSYSTEM R RH RC

Strona 32 - PART NO. 37-7343B

9INSTALLATIONInstallationWiring Guide for Equipment AccessoriesHMHM2Non-PoweredHumidierTransformerRCHM DRYRHHM2Fig. 3 - Humidier. HM terminal provid

Komentarze do niniejszej Instrukcji